Mast and Pole Mounting

Safety first

Erecting and climbing masts is hazardous. Before any mast work:

Mast options

Guy wires

Masts more than about 3-4 meters free-standing (and any telescoping push-up mast above roughly 4 m) need guy wires. Use three guys at 120 degree intervals (a triangular arrangement). Use stainless cable or UV-resistant rope. Guy at 2/3 height and near the top. The exact threshold depends on mast type, antenna wind load, and exposure - guy sooner for heavier antennas or windy sites.

Grounding and lightning protection

Ground the mast and antenna with a bonding/down conductor not smaller than #10 AWG copper (NEC 810.21); #8 AWG or larger exceeds this minimum and is fine. If you drive a separate ground rod for the antenna, it must be bonded to the building's main grounding electrode system with at least a #6 AWG copper conductor (NEC 810/250) - grounding the mast to its own isolated rod without bonding to building ground creates a dangerous ground-potential difference and is a code violation. Install a coaxial lightning arrestor rated for 915 MHz at the building entry point and bond it to building ground. See the dedicated grounding and lightning protection page for full detail.

Key rules