# Charge Controller Selection and Configuration

The charge controller is the brain of your solar power system - it manages battery charging, prevents overcharge and deep discharge, and in MPPT controllers, optimizes power extraction from the solar panel. Choosing the right charge controller significantly affects system efficiency and longevity.

## PWM vs. MPPT: Which to Choose

<table id="bkmrk-featurepwmmppt-effic"><thead><tr><th>Feature</th><th>PWM</th><th>MPPT</th></tr></thead><tbody><tr><td>Efficiency</td><td>70-75%</td><td>93-97%</td></tr><tr><td>Cost</td><td>$5-20</td><td>$30-150</td></tr><tr><td>Solar panel voltage matching</td><td>Must match battery voltage closely</td><td>Works with any panel voltage above battery voltage</td></tr><tr><td>Best for small systems</td><td>Under 5W with matched panel/battery</td><td>5W+ or when panel voltage exceeds battery voltage</td></tr><tr><td>Cold weather performance</td><td>Good</td><td>Excellent (harvests more from cold-weather voltage boost)</td></tr></tbody></table>

**Recommendation:** Use MPPT for any permanent deployment. The efficiency gain pays for the cost premium within 1-2 years in most climates, and MPPT controllers last longer and provide better battery protection.

## Victron SmartSolar MPPT 75/10: The Standard Choice

The Victron SmartSolar 75/10 ($45-55, as of 2026-06-08) is the most popular choice for LoRa mesh solar nodes:

- Input: up to 75V open-circuit panel voltage, 10A max battery charge current
- Supports 12V and 24V battery systems
- Bluetooth monitoring via Victron Connect app - see real-time voltage, current, and charge state from your phone
- Load output: switched 15A continuous output (short-circuit proof) with built-in low-voltage disconnect that protects the battery. Note the 10A figure is the battery charge current rating, not the load output rating.
- Temperature compensation for accurate charging - this adjusts charge voltage for lead-acid chemistry; LiFePO4 does not use it, so disable it even in cold climates (see configuration below)

```
# Victron MPPT configuration for LiFePO4 battery (12V system):
Charge algorithm: Li-Ion
Absorption voltage: 14.4V (range 14.2-14.6V; do not float here)
Float voltage: 13.5V
Low voltage disconnect: 12.0V (operating LVD for longevity, ~10-20% SoC remaining; this is NOT 80% DOD protection. The hard BMS under-voltage cutoff is lower, ~10-10.8V)
Temperature compensation: Disabled for LiFePO4 (temp compensation is a lead-acid feature)

# For LiPo (3.7V single cell, 4.2V max):
# Use a TP4056 Li-Ion charger module, not a Victron
# Victron 75/10 is designed for 12V+ systems
```

## Load Output vs. Direct Battery Connection

Most MPPT controllers have a "load output" - a switched output that turns off automatically when the battery voltage drops below a set threshold:

- **Advantages of load output:** Built-in low-voltage disconnect protects battery; the controller manages when to power the node vs. when to conserve battery for recovery
- **Disadvantages:** Load output current limit (typically 10-15A) may not support higher-power loads; adds a small voltage drop (0.1-0.5V)

**Best practice:** Connect your node through the load output for automatic low-voltage protection. Connect any monitoring equipment (Pi) directly to the battery with its own cutoff relay if the Pi exceeds the load output current limit.

## Solar Panel Tilt Optimization

```
# A good annual-average tilt is approximately equal to your latitude.
# (A common refinement is latitude * ~0.76 per NREL studies, since the
# true annual optimum is somewhat below latitude.) The latitude * 0.9
# + offset formulas you may see elsewhere are season-specific (winter),
# not the annual-maximum rule.

# Annual-average examples (tilt ~ latitude):
# Portland (45.5°N): ~45 degrees from horizontal
# Dallas (32.8°N): ~33 degrees
# Phoenix (33.4°N): ~33 degrees
# Chicago (41.8°N): ~42 degrees

# For winter optimization (maximize December-February output):
# Tilt angle = latitude + 15 degrees

# For snow-shedding (prevents accumulation that blocks panel):
# Tilt angle = 45 degrees minimum; 60 degrees ideal in heavy snow climates
```